TUNNEL FOR FREEZING
|
|
|
|
with continuous cryogenic gas "NITROGEN" for the freezing of whole or cut potatoes
|
|
TUNNEL OF FREEZING COLD GAS (NITROGEN)
For the freezing of whole or cut potatoes:
|
|
Project Data:
|
|
-
|
Ability 'freezing: 1000 Kg./h .;
|
|
-
|
Product features: potatoes or other;
|
|
-
|
Disposition on the tape: in bulk;
|
|
-
|
Incoming product temperature: + 20 ° C .;
|
|
-
|
Output product temperature: -18 ° C .;
|
|
-
|
Expected freezing time: approximately 6 minutes;
|
|
-
|
Operating temperature: -70 ° C;
|
|
-
|
NITROGEN consumption per Kg. Product: Kg.
|
|
1.45. The model is proposed: M10 / 140-V16
|
|
General Characteristics:
|
|
-
|
Base composed of a sturdy tubular and angular structure of acc . stainless steel AISI 304, with leveling feet in acc . stainless
|
|
-
|
External casing constructed from polyurethane foam panels (120 mm thick), covered with acc . stainless steel AISI 304.
|
|
-
|
Conveyor belt composed of a frame in sections and central guides in polizene ; containment side rails in shaped sheet metal; the net is built with V-shaped links and side chain, the whole is in AISI 304. Network carpet dimensions: 1000xlung.attile width 8000 (+400 supply side).
|
|
-
|
The belt is driven by a gear motor ( PE KW 1.1) controlled by an ITACHI inverter, the crossing time of the product is variable according to the type of product.
|
|
-
|
The ventilation system is provided by 12 fans of 330 and 400 mm diameter placed on the ceiling.
|
|
|
These fans are driven by motors ( PE cad / KW 0.75),
|
|
|
all protected by aluminum sleeves, which support the guide bearings
|
|
-
|
The lifting of the casing (for inspection and cleaning of the tape) is allowed by
four angular transmissions with trapezoidal screws , driven by a single gear motor ( PE KW 1.1) placed under the base.
|
|
-
|
the injection and regulation system of the cryogenic gas, is realized through nozzles calibrated sprayers, placed on special ramps connected to two solenoid valves.
|
|
|
All this is controlled by a PLC using a PT100 thermoresistance .
|
|
-
|
The exhaust gas extraction system is allowed by an aspirator placed on one shelf applied in proximity ( PE KW 1.1).
|
|
|
This vacuum cleaner is connected to one
|
|
|
three-way valve with adjustment throttle, via a flexible hose
|
|
|
The three-way valve
|
|
|
it is placed above the tunnel on the supply side.
|
|
-
|
The electrical panel consists of an acc . INOX, where they are assembled all electrical equipment and the PLC, which programs the entire cycle of pre-set freezing based on the characteristics of the product being processed.
|
|
-
|
IP55 electrical system with panel with stainless steel casing
|
|
-
|
accident prevention protections according to CE regulations
|
|
-
|
supplied with use and maintenance manual
|
|
Technical data
|
|
-
|
Total electrical power KW 13.
|
| |
|
|